24/7 gas emergency — no heat, no hot water, gas smell Gas Safe registered · All Leeds postcodes
Gas Engineer
To The RescueLeeds
Call 24/70113 490 0490
Worcester boiler with copper pipework, service valves and a MagnaClean filter

Boilers

Boiler installation and repair in Leeds

Sized on your property, fitted by a Gas Safe registered engineer, flushed and filtered, commissioned properly and registered for your warranty.

Which type

Three kinds of boiler, and when each is right

Most of the disappointment with a new boiler comes from fitting the wrong type, not from fitting it badly. Here is the honest version of each.

Vaillant ecoFIT pure combi boiler with copper pipework and condensate pipe

Combi

Heats water on demand, no cylinder and no tank. Right for most one-bathroom houses and flats, and the least disruptive swap if you already have one. The limit is real though: a combi cannot serve two outlets properly at once, so a second shower will always disappoint somebody.

Vaillant system boiler beside a Tempest unvented hot water cylinder with insulated pipework

System boiler & cylinder

Stores hot water in an unvented cylinder, so several outlets can run together at mains pressure. The right answer for houses with two or more bathrooms. Costs more and needs cupboard space, but it is the difference between a shower that works and one that stutters.

Worcester boiler with copper pipework, service valves and a MagnaClean filter

Heat-only (regular)

The traditional setup with a cylinder and usually a tank in the loft. Often the sensible choice in older properties where the pipework and radiators suit it and a full conversion would mean tearing the house apart for limited gain.

The install

Six stages, every replacement

01

Survey, not a guess

Bathrooms counted, radiators counted, mains flow rate measured at the tap. That is what sizes a boiler — not the size of the old one.

02

Written fixed price

Boiler, flue, filter, controls, labour and making good, all itemised. No day-rate surprises.

03

Old unit out

Drained down, disconnected and removed. Back boilers and tanks taken out too where the job calls for it.

04

Flush and filter

System cleaned and a magnetic filter fitted on the return. Skip this and a new boiler inherits the last one’s sludge.

05

Install and pipe

Hung, piped, flued, condensate run to a proper termination, gas soundness tested.

06

Commission and register

Combustion analysed, pressures set, controls explained, and the installation registered with Gas Safe and the manufacturer for your warranty.

Boiler packed in?

We take emergency calls 24 hours a day across Leeds. Tell us the fault code if it’s showing one.

Call 0113 490 0490

Repairs

Most boilers don’t need replacing

A boiler that has locked out is usually protecting itself, and the fault behind it is often a part rather than the whole appliance. Diagnosis first, recommendation second.

  • Pressure that keeps droppingNearly always a small leak somewhere on the system, a failed expansion vessel or a weeping pressure relief valve.
  • Locking out repeatedlyIgnition, flame sensing, a blocked condensate in cold weather, or a fan or PCB on the way out.
  • Hot water but no heatingClassic diverter valve symptom, and a part-level repair rather than a new boiler.
  • Banging or kettlingScale or sludge on the heat exchanger. Worth dealing with before it shortens the boiler’s life.
  • When we say replaceObsolete parts, a failed heat exchanger, or repair costs approaching replacement. We will show you the maths.
Boiler and filter installed by Gas Engineer To The Rescue Leeds

Recent installs

Boilers we’ve fitted round Leeds

Viessmann wall mounted boiler with copper pipework, isolation valves and a system filter
Viessmann boiler, full re-pipeFlow and return dropped, isolation valves on every leg and a filter on the return before commissioning.
Vaillant ecoFIT pure combi boiler with copper pipework and condensate pipe
Vaillant ecoFIT changeoverOld boiler out, new one hung and piped, condensate run to a proper termination.
Alpha combi boiler installed in a loft on a ply board with insulated pipework and a CO alarm
Combi in a loft spaceAlpha combi boarded, boiler-mounted on ply, pipework insulated and a CO alarm fitted alongside.
New Ideal combi boiler installed on a plastered wall with copper pipework
Combi changeoverIdeal combi in and commissioned, gas and water connections renewed rather than reused.
Worcester boiler installed on a stud wall with copper pipework and a magnetic filter
Boiler on an open stud wallPiped and filtered while the wall was still open, so nothing had to be chased in afterwards.
New white boiler flue run and wall terminal fitted above a boiler
Flue re-routeNew run out through the wall on a replacement, sealed and supported to spec.

FAQs

Boiler questions

How do I know what size boiler I need?

By counting radiators and bathrooms and measuring the incoming mains flow rate, not by matching whatever is on the wall. Oversized boilers cycle on and off and wear out faster; undersized ones never keep up. A survey takes twenty minutes and settles it.

Can I just have the same again?

Often that is exactly right, and if so we will say so. But if the old one was the wrong choice for the house, fitting the same again repeats the mistake for another decade. Worth ten minutes of conversation.

Is a combi a bad idea in a big house?

In a house with two or more bathrooms in regular use, generally yes. A combi heats water as it flows, so two outlets at once split the flow between them. A system boiler and an unvented cylinder solves it properly.

Do you remove back boilers?

Yes. They sit behind a fireplace and need the fire and surround dealt with as well as the boiler, so it is a bigger job than a straight swap, and we will be clear about that in the quote.

Will a new boiler need a filter fitting?

Yes, and most manufacturers now require one for the warranty. It catches the magnetic debris that circulates in every heating system and it is the single cheapest thing you can do to protect a new boiler.

Do I need a powerflush before a new boiler?

Not always. A clean system with a filter may only need a chemical cleanse. A system full of black sludge with cold-bottomed radiators needs a proper flush. We test the water rather than assuming either way.

How long is the warranty?

It depends on the manufacturer and the model, and in almost every case it depends on the installation being registered and the boiler being serviced annually. We register it for you and tell you what the terms actually require.

Get in touch

Get a fixed price for a new boiler

Tell us what you have now and how many bathrooms you run. We come out, measure the flow rate and give you a written fixed price.

Call us, any hour

0113 490 0490

No heat, no hot water or a boiler locked out — ring rather than email.

  • Hours24 hours a day, 7 days a week — bank holidays included
  • Emailinfo@plumbertotherescue.co.uk
  • AreaLeeds and the surrounding areas
  • RegistrationAll gas work by a Gas Safe registered engineer

Send us the details

No obligation. We’ll tell you honestly whether it’s a repair or a replacement.

We come out, look at the property and give you a written fixed price. No obligation.

☎ Call now Get a quote